1. Select the housing and the corresponding battery.
Housing
Type and battery
Picture
Size & weight
Medium
Sheat material
Item no.
Standard IP 60
Design housing with 230 mAh battery
27 x 16 x 53 mm (W x H x L) approx. 20 g
Air
PC, not encapsulated
145B15
Design housing with 1000 mAh battery
39 x 23 x 72 mm (W x H x L) approx. 56 g
Air
PC, not encapsulated
145B7
Waterproof IP 67
Silicon tube with 230 mAh battery
20 x 14 x 62 mm (W x H x L) approx. 18 g
Air, various liquids
Silicon, encapsulated
145B4
Design housing with 230 mAh battery
27 x 16 x 53 mm (W x H x L) approx. 27 g
Air, various liquids
PC, encapsulated
145B16
Design housing with 1000 mAh battery
39 x 23 x 72 mm (W x H x L) approx. 64 g
Air, various liquids
PC, encapsulated
145B8
2. Select the configuration.
You can select various internal sensors as well as up to five external sensors or connectors.
Measured parameter / Measurement/ storage rate
Technical data
Internal
External (according to cable length)
0.20 m
1.00 m
1.60 m
Temperature
1/s to every 12 h
Working range: external: -40...+125 °C internal: -20...+65 °C Max. deviation: ±0.1 °C (-25...+55 °C) ±0.3 °C (-40...+125 °C)
Item no. T9
Item no. FT9/020
Item no. FT9/100
Item no. FT9/160
Working range: -55...+125 °C Max. deviation: ±0.5 °C (10...+70 °C) ±2 °C (-55...+125 °C)
only available externally
Item no. FT2/020
Item no. FT2/100
Item no. FT2/160
Connector for thermal element of Type K (without sensor)
4/s* to every 12 h *(1/s in combination with A4 sensor)
Working range: -200...+1350 °C
only available externally
Item no. FT3/020
Item no. FT3/100
Item no. FT3/160
Humidity with integrated temperature
1/s to every 12 h
Working range: 0...100 % rel. humidity external: -40...+125 °C internal: -20...+65 °C Max. deviation: ±2 % rel. humidity (10...80 %, +25 °C) ±3 % rel. Feuchte (80...100 %, +25 °C)
Item no. H3
Item no. FH3/020
Item no. FH3/100
Item no. FH3/160
Air pressure absolute, with integrated temperature
Internal: 1/s to every 12 h External: 10/s* to every 12 h *(1/s in combination with A4 sensor)
Working range: 10...2000 mbar absolute external: -40...+85 °C internal: -20...+65 °C Max. deviation: ±2 mbar (1% FS) (750...1100 mbar absolute, +25 °C)
Item no. P5
Item no. FP10/020
Item no. FP10/100
Item no. FP10/160
Working range: 0...14 bar absolute -20...+65 °C Max. deviation: ±50 mbar (1% FS) (1...10 bar abs., +25 °C)
Item no. P7
only available on request
Item no. FP7/020
Item no. FP7/100
Item no. FP7/160
Fluid pressure with integrated temperature
Internal: 1/s to every 12 h External: 10/s* to every 12 h *(1/s in combination with A4 sensor)
Material in contact with media:
Stainless Steel AISI 316L (DIN 1.4404 / 1.4435)
O-rings: Viton® 70° Sh
Working range: -1000...3000 mbar relative -20...+85 °C Max. deviation: ±30 mbar (1% FS)
only available externally
Item no. FP9/020
Item no. FP9/100
Item no. FP9/160
Working range: 0...3000 mbar absolute -20...+85 °C Max. deviation: ±30 mbar (1% FS)
only available externally
Item no. FP3/020
Item no. FP3/100
Item no. FP3/160
Working range: 0...30 bar absolute -20...+85 °C Max. deviation: ±0.3 bar (1% FS)
only available externally
Item no. FP4/020
Item no. FP4/100
Item no. FP4/160
Working range: 0...400 bar absolute -20...+85 °C Max. deviation: ±4 bar (1% FS)
only available externally
Item no. FP8/020
Item no. FP8/100
Item no. FP8/160
Working range: 0...1000 bar absolute -20...+85 °C Max. deviation: ±10 bar (1% FS)
only available externally
Item no. FP12/020
Item no. FP12/100
Item no. FP12/160
3-axis-acceleration (static)
50/s to every 12 h
±15 g -20...+65 °C ±0.15 g (0...5 g, +25 °C) ±0.25 g (5...10 g, +25 °C) ±0.45 g (10...15 g, +25 °C)
Item no. A
Item no. FA/020
Item no. FA/100
Item no. FA/160
3-axis-acceleration with Fast Peak (1 kHz)
50/s to every 12 h
Item no. A4
Item no. FA4/020
Item no. FA4/100
Item no. FA4/160
Light
1/s to every 12 h
Working range: 0...83'000 lx Max. sensitivity at 550 nm
Item no. L3
Item no. FL3/020
Item no. FL3/100
Item no. FL3/160
Connection for strain gauges
Characteristics:
full bridge
rated output 1 mV/V
bridge voltage 3 V
only available externally
Item no. FD/020
Item no. FD/100
Item no. FD/160
Analogue inputs (resolution: 12 bit)
50/s* to every 12 h *(1/s in combination with A4 sensor)
Input configuration:
only available externally
Exxxx/020
Exxxx/100
Exxxx/160
Control terminal
Characteristics:
Alarm output
Input for starting and stopping data recording
3 V voltage output
only available externally
Item no. FY/020
Item no. FY/100
Item no. FY/160
3. Would you like to expand the memory capacity of your MSR145 to over 1 billion measured values?
Please order the expansion slot for plugging-in a standard microSD card here.
Item no.
Expansion slot for microSD card (available only for design housing B7 and B8)
Please note that:
this expansion slot with plugged-in microSD card only meets the protection category IP60, even with the design housing B8,
one formatted and ready for use microSD card (≥4GB) is included.
N10006
4. Contact us for prices and delivery terms!
Make a price enquiry by telephone, fax or e-mail
The following codes denote the type of datalogger and sensors you have selected. When making price enquiries by telephone, fax or e-mail, please have the codes ready.