{"id":1432,"date":"2017-06-22T22:01:03","date_gmt":"2017-06-22T22:01:03","guid":{"rendered":"http:\/\/localhost\/msrbeta\/en\/?p=1432"},"modified":"2020-09-09T08:11:37","modified_gmt":"2020-09-09T08:11:37","slug":"data-loggers-help-identify-leakages-in-vacuum-chambers","status":"publish","type":"post","link":"https:\/\/www.msr.ch\/en\/data-loggers-help-identify-leakages-in-vacuum-chambers\/","title":{"rendered":"Recording measured data: Logging vacuum data"},"content":{"rendered":"<p><span class=\"line-divide\">\u00a0<\/span><a title=\"Datenlogger MSR255\" href=\"https:\/\/www.msr.ch\/en\/datalogger-display-sensors-msr255\/\"><strong>Data Logger MSR255<\/strong><\/a><\/p>\n<p>\n <a title=\"The MSR255 data logger by MSR Electronics GmbH is a compact multi-talent.\" href=\"..\/..\/..\/images\/fields-application\/Climeworks\/msr255-universal-data-logger-with-display.jpg\" class=\"msr-image-popup\" ><img loading=\"lazy\" decoding=\"async\" src=\"..\/..\/..\/images\/fields-application\/Climeworks\/msr255-universal-data logger-with-display_155.jpg\" alt=\"The MSR255 data logger by MSR Electronics GmbH is a compact multi-talent.\" width=\"155\" height=\"103\" border=\"0\" \/><\/a><\/p>\n<p><a title=\"The CO&lt;sub&gt;2&lt;\/sub&gt; capture demonstrator by Climeworks is a self-sufficient, mobile CO&lt;sub&gt;2&lt;\/sub&gt; separation device that separates up to 8 kg of CO&lt;sub&gt;2&lt;\/sub&gt; per day from ambient air. Picture source: Climeworks AG\" href=\"..\/..\/..\/images\/fields-application\/Climeworks\/CO2-capture-demonstrator.jpg\" class=\"msr-image-popup\" ><img loading=\"lazy\" decoding=\"async\" src=\"..\/..\/..\/images\/fields-application\/Climeworks\/CO2-capture-demonstrator_155.jpg\" alt=\"The CO2 capture demonstrator by Climeworks is a self-sufficient, mobile CO2 separation device that separates up to 8 kg of CO2 per day from ambient air. Picture source: Climeworks AG\" width=\"155\" height=\"103\" border=\"0\" \/><\/a><\/p>\n<h2>MSR255 Data Logger helps identify leakages in vacuum chambers<\/h2>\n<p class=\"article_source\">Authors: Nic Piatkowski, PhD, Climeworks AG, Gabriela Zumkehr, MSR Electronics GmbH<\/p>\n<p class=\"article_intro\">Mini data loggers are proving to be useful tools for recording and storing physical measurands in diverse fields of industry and science. As the present user report concerning MSR data loggers at Climeworks AG \u2013 an internationally recognised developer of CO<sub>2<\/sub> collectors \u2013 shows, these small data recording devices are able to do much more than has been known to date with respect to their typical applications, such as monitoring transport conditions.<\/p>\n<p>Whilst CO<sub>2<\/sub> has fallen into disrepute as a climate killer, it does not only have drawbacks. This gas is, for example, used as a protective atmosphere when packaging food and helps accelerate the growth of plants. With the innovative technologies of Zurich-based <a title=\"Website of Climeworks AG\" href=\"http:\/\/www.climeworks.com\/\" target=\"_blank\" rel=\"noopener\">Climeworks AG<\/a>, a spinoff of ETH Zurich, the gas is produced virtually CO<sub>2<\/sub>-neutral, using waste heat. With the CO<sub>2<\/sub> collector, Climeworks has developed a technical solution that extracts highly concentrated CO<sub>2<\/sub> from air with a low expenditure of energy. This \u201crenewable\u201d CO<sub>2<\/sub> is the ideal raw material for many industrial applications, including synthetic automotive fuels such as Diesel, petrol and methane. The car manufacturer Audi, for instance, has also recognised the benefit of these CO<sub>2<\/sub> collectors; it plans to integrate and test the world\u2019s first industrial module of a CO<sub>2<\/sub> collector in a synthetic fuel production plant.<\/p>\n<h3>What do the CO<sub>2<\/sub> collectors do?<\/h3>\n<p>The Climeworks process is based on the cyclical adsorption and desorption of CO<sub>2<\/sub> from ambient air. During the adsorption process, ambient air passes through a specially developed adsorber system, which contains a sorbent that binds the CO<sub>2<\/sub>. As soon as the sorbent is saturated with CO<sub>2<\/sub>, the process is switched to the desorption phase in which the sorbent releases the isolated CO<sub>2<\/sub>. For this purpose, it his heated to approx. 80-130 \u00b0C by means of low-temperature heat and exposed to a rough vacuum in a vacuum chamber. The company had such a vacuum chamber constructed for a new product line and tested it with respect to leakages and structural strength using a mini data logger.<\/p>\n<h3>MSR255 Data Logger monitors vacuum<\/h3>\n<p><a title=\"The universal MSR255 data logger in use on the vacuum chamber that has been pumped down to a pressure of 3.1 mbar absolute (on the far left): Here it monitors pressure and temperature. The laboratory power supply in the background powers the pressure sensor, which has been attached to the KF flange of the vacuum chamber, for a pressure of 0-1 bar absolute. The temperature sensor (white cable) is attached to the chamber wall. Picture source: Climeworks AG\" href=\"..\/..\/..\/images\/fields-application\/Climeworks\/data-logger-msr255-vacuum-chamber.jpg\" class=\"msr-image-popup\" ><img loading=\"lazy\" decoding=\"async\" class=\"alignright\" src=\"..\/..\/..\/images\/fields-application\/Climeworks\/data-logger-msr255-vacuum-chamber_200.jpg\" alt=\"The universal MSR255 data logger in use on the vacuum chamber that has been pumped down to a pressure of 3.1 mbar absolute (on the far left): Here it monitors pressure and temperature. The laboratory power supply in the background powers the pressure sensor, which has been attached to the KF flange of the vacuum chamber, for a pressure of 0-1 bar absolute. The temperature sensor (white cable) is attached to the chamber wall. Picture source: Climeworks AG\" width=\"200\" height=\"133\" border=\"0\" \/><\/a> Climeworks selected a <a title=\"MSR255 Data Logger: Robust multi-talent with LCD screen\" href=\"\/en\/product\/msr255.php\">data logger of the type MSR255<\/a> by the Swiss measurement technology company MSR Electronics GmbH for the acceptance tests of the vacuum chamber. This compact miniature measurement technology laboratory has a large memory (2 million measured values) and an LC display that can be individually configured; it is ideal for flexible, on-site measurements \u2013 even under special ambient conditions. In its full version, this data logger is able to record up to five different measurands at the same time and to store their values. However, at Climeworks the MSR255 was used with an external temperature sensor and analogue inputs for connecting Climeworks\u2019 own pressure sensor, which was placed inside the vacuum chamber. With the logger, the company was able to provide accurate information regarding the pressure ratios and pressure patterns for each time unit and, in particular, observe a pressure loss caused by a leakage.<\/p>\n<h3>Leakages are quickly identified<\/h3>\n<p>For the acceptance test, at the manufacturer\u2019s premises, the pressure within the vacuum chamber was reduced to approximately 1 mbar absolute. Temperature and pressure values were monitored throughout, to check the quality of the seal. The pressure was measured with a 2-wire\/24 V pressure sensor with 4&#8230;20 mA output for a pressure of 0-1 bar absolute. <a title=\"Pressure (orange curve) and temperature (blue curve) in the chamber when evacuating air (only pressures below 100 mbar absolute are shown) and when maintaining the vacuum. When evacuating air, the pressure rapidly drops to approx. 1 mbar absolute (on the far left in the diagram, orange curve). The increase in pressure from approx. 3 pm (15.00 hours, right third of the diagram) indicates the presence of a leakage, which was identified and sealed as a result of this measurement. The re-evacuation of air (reduction in pressure) after the occurrence of the leakage can also be observed. Picture source: Climeworks AG\" href=\"..\/..\/..\/images\/fields-application\/Climeworks\/chart-pressure-temperature-pressure-in-the-vacuum-chamber.jpg\" class=\"msr-image-popup\" ><img loading=\"lazy\" decoding=\"async\" class=\"alignleft\" src=\"..\/..\/..\/images\/fields-application\/Climeworks\/chart-pressure-temperature-pressure-in-the-vacuum-chamber_200.jpg\" alt=\"Pressure (orange curve) and temperature (blue curve) in the chamber when evacuating air (only pressures below 100 mbar absolute are shown) and when maintaining the vacuum. When evacuating air, the pressure rapidly drops to approx. 1 mbar absolute (on the far left in the diagram, orange curve). The increase in pressure from approx. 3 pm (15.00 hours, right third of the diagram) indicates the presence of a leakage, which was identified and sealed as a result of this measurement. The re-evacuation of air (reduction in pressure) after the occurrence of the leakage can also be observed. Picture source: Climeworks AG\" width=\"200\" height=\"133\" border=\"0\" \/><\/a> It was powered by a laboratory power supply and connected with the 4&#8230;20 mA analogue input port of the MSR255 data logger. The logger was programmed so that the 4&#8230;20 mA signal was rescaled directly into an output value of 0-1 bar (absolute). The temperature of the vacuum chamber was measured with the integrated temperature sensor of the MSR255, which had been attached to the wall of the vacuum chamber. The measured values are analysed by means of the <a title=\"For efficient data collection and analysis: MSR PC Software\" href=\"\/en\/support\/pcsoftware.html\">MSR PC software<\/a>, which delivers very meaningful measurement diagrams. The developments of the temperature and pressure values evident from this, as well as the known volume of the vacuum chamber, were used to determine the increase of the air mass in the chamber via the ideal gas law and thus the leakage rate was calculated. This practical example already shows that the miniature data loggers can be used profitably in versatile metrological application scenarios, saving both time and costs \u2013 the spectrum of applications ranges from logistics, through machine and transportation monitoring, to laboratory measurement technology, automotive test bench technology and even aerospace.<\/p>\n<p style=\"margin-top: 25px;\"><a title=\"Contact MSR Electronics GmbH\" href=\"\/en\/contact\/\">Can we also help you with your measuring tasks? We would be pleased to advise you!<\/a><\/p>\n<h3>\nYou may also be interested in these articles:<\/h3>\n<ul>\n<li><a title=\"MSR255 Data Logger: Robust multi-talent with LCD screen\" href=\"\/en\/product\/msr255.php\">MSR255 Data Logger: Robust multi-talent with LCD screen<\/a><\/li>\n<li><a title=\"Hot on the trail of energy loss in compressed air systems\" href=\"\/en\/fields-application\/data-logger-for-flow-rate-measurements-and-record-pressure-values-for-festo.html\">Energy Savings division of Festo using MSR145 Data Loggers: Hot on the trail of energy loss in compressed air systems<\/a><\/li>\n<li><a title=\"MSR data loggers for environmental monitoring applications\" href=\"\/en\/fields-application\/MSR255-Data-Loggers-environmental-monitoring-applications.html\">MSR255 Data Loggers for environmental monitoring applications<\/a><\/li>\n<li><a title=\"The fast way to the right datalogger\" href=\"\/en\/product\/datalogger.php\">The fast way to the right Data Logger<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>For acceptance tests of a vacuum chamber, Climeworks AG \u2013 an internationally successful developer of CO2 collectors \u2013 selected a data logger of the type MSR255 by MSR Electronics GmbH.<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[12,13],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v22.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Data Logger helps identify leakages in vacuum chambers<\/title>\n<meta name=\"description\" content=\"MSR255 data logger in search of leakages in vacuum chambers. For tests of a vacuum chamber, Climeworks, developer of CO2 collectors, selected a data logger\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.msr.ch\/en\/data-loggers-help-identify-leakages-in-vacuum-chambers\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Data Logger helps identify leakages in vacuum chambers\" \/>\n<meta property=\"og:description\" content=\"MSR255 data logger in search of leakages in vacuum chambers. For tests of a vacuum chamber, Climeworks, developer of CO2 collectors, selected a data logger\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.msr.ch\/en\/data-loggers-help-identify-leakages-in-vacuum-chambers\/\" \/>\n<meta property=\"og:site_name\" content=\"EN MSR Data loggers\" \/>\n<meta property=\"article:published_time\" content=\"2017-06-22T22:01:03+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-09-09T08:11:37+00:00\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.msr.ch\/en\/data-loggers-help-identify-leakages-in-vacuum-chambers\/\",\"url\":\"https:\/\/www.msr.ch\/en\/data-loggers-help-identify-leakages-in-vacuum-chambers\/\",\"name\":\"Data Logger helps identify leakages in vacuum chambers\",\"isPartOf\":{\"@id\":\"https:\/\/www.msr.ch\/en\/#website\"},\"datePublished\":\"2017-06-22T22:01:03+00:00\",\"dateModified\":\"2020-09-09T08:11:37+00:00\",\"author\":{\"@id\":\"https:\/\/www.msr.ch\/en\/#\/schema\/person\/9f5e8ed5c17dd1588344ef6ea5492ed7\"},\"description\":\"MSR255 data logger in search of leakages in vacuum chambers. For tests of a vacuum chamber, Climeworks, developer of CO2 collectors, selected a data logger\",\"breadcrumb\":{\"@id\":\"https:\/\/www.msr.ch\/en\/data-loggers-help-identify-leakages-in-vacuum-chambers\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.msr.ch\/en\/data-loggers-help-identify-leakages-in-vacuum-chambers\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.msr.ch\/en\/data-loggers-help-identify-leakages-in-vacuum-chambers\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.msr.ch\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Recording measured data: Logging vacuum data\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.msr.ch\/en\/#website\",\"url\":\"https:\/\/www.msr.ch\/en\/\",\"name\":\"EN MSR Data loggers\",\"description\":\"MSR Electronics GmbH\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.msr.ch\/en\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.msr.ch\/en\/#\/schema\/person\/9f5e8ed5c17dd1588344ef6ea5492ed7\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/www.msr.ch\/en\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/2d44aa9cd968ccac7142267b4b988313?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/2d44aa9cd968ccac7142267b4b988313?s=96&d=mm&r=g\",\"caption\":\"admin\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Data Logger helps identify leakages in vacuum chambers","description":"MSR255 data logger in search of leakages in vacuum chambers. For tests of a vacuum chamber, Climeworks, developer of CO2 collectors, selected a data logger","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.msr.ch\/en\/data-loggers-help-identify-leakages-in-vacuum-chambers\/","og_locale":"en_GB","og_type":"article","og_title":"Data Logger helps identify leakages in vacuum chambers","og_description":"MSR255 data logger in search of leakages in vacuum chambers. For tests of a vacuum chamber, Climeworks, developer of CO2 collectors, selected a data logger","og_url":"https:\/\/www.msr.ch\/en\/data-loggers-help-identify-leakages-in-vacuum-chambers\/","og_site_name":"EN MSR Data loggers","article_published_time":"2017-06-22T22:01:03+00:00","article_modified_time":"2020-09-09T08:11:37+00:00","author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"admin","Estimated reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.msr.ch\/en\/data-loggers-help-identify-leakages-in-vacuum-chambers\/","url":"https:\/\/www.msr.ch\/en\/data-loggers-help-identify-leakages-in-vacuum-chambers\/","name":"Data Logger helps identify leakages in vacuum chambers","isPartOf":{"@id":"https:\/\/www.msr.ch\/en\/#website"},"datePublished":"2017-06-22T22:01:03+00:00","dateModified":"2020-09-09T08:11:37+00:00","author":{"@id":"https:\/\/www.msr.ch\/en\/#\/schema\/person\/9f5e8ed5c17dd1588344ef6ea5492ed7"},"description":"MSR255 data logger in search of leakages in vacuum chambers. For tests of a vacuum chamber, Climeworks, developer of CO2 collectors, selected a data logger","breadcrumb":{"@id":"https:\/\/www.msr.ch\/en\/data-loggers-help-identify-leakages-in-vacuum-chambers\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.msr.ch\/en\/data-loggers-help-identify-leakages-in-vacuum-chambers\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.msr.ch\/en\/data-loggers-help-identify-leakages-in-vacuum-chambers\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.msr.ch\/en\/"},{"@type":"ListItem","position":2,"name":"Recording measured data: Logging vacuum data"}]},{"@type":"WebSite","@id":"https:\/\/www.msr.ch\/en\/#website","url":"https:\/\/www.msr.ch\/en\/","name":"EN MSR Data loggers","description":"MSR Electronics GmbH","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.msr.ch\/en\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/www.msr.ch\/en\/#\/schema\/person\/9f5e8ed5c17dd1588344ef6ea5492ed7","name":"admin","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.msr.ch\/en\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/2d44aa9cd968ccac7142267b4b988313?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2d44aa9cd968ccac7142267b4b988313?s=96&d=mm&r=g","caption":"admin"}}]}},"_links":{"self":[{"href":"https:\/\/www.msr.ch\/en\/wp-json\/wp\/v2\/posts\/1432"}],"collection":[{"href":"https:\/\/www.msr.ch\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.msr.ch\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.msr.ch\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.msr.ch\/en\/wp-json\/wp\/v2\/comments?post=1432"}],"version-history":[{"count":10,"href":"https:\/\/www.msr.ch\/en\/wp-json\/wp\/v2\/posts\/1432\/revisions"}],"predecessor-version":[{"id":3763,"href":"https:\/\/www.msr.ch\/en\/wp-json\/wp\/v2\/posts\/1432\/revisions\/3763"}],"wp:attachment":[{"href":"https:\/\/www.msr.ch\/en\/wp-json\/wp\/v2\/media?parent=1432"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.msr.ch\/en\/wp-json\/wp\/v2\/categories?post=1432"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.msr.ch\/en\/wp-json\/wp\/v2\/tags?post=1432"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}