{"id":1524,"date":"2017-06-25T15:30:16","date_gmt":"2017-06-25T15:30:16","guid":{"rendered":"http:\/\/localhost\/msrbeta\/en\/?p=1524"},"modified":"2017-06-25T15:56:12","modified_gmt":"2017-06-25T15:56:12","slug":"data-logger-measure-acceleration-in-pneumatic-tube-transport","status":"publish","type":"post","link":"https:\/\/www.msr.ch\/en\/data-logger-measure-acceleration-in-pneumatic-tube-transport\/","title":{"rendered":"Evaluation of a fast single sample pneumatic tube system"},"content":{"rendered":"<p><span class=\"line-divide\">&nbsp;<\/span><br \/>\n<a href=\"..\/..\/..\/images\/msr145\/Mini-Datalogger-MSR145.jpg\" title=\"This thumb-sized Swiss Quality MSR145 data logger records over 2\u2009000\u2009000 measured values - with an optional microSD card, even over a billion measured values - and is ideal for long-term measurements. It is capable of simultaneously measuring and recording a variety of measures such as temperature, humidity, pressure, 3-axis acceleration and light. All measured values can be rapidly transferred to a PC or laptop via the USB interface or microSD card for data analysis purposes.\" class=\"msr-image-popup\" ><img loading=\"lazy\" decoding=\"async\" src=\"..\/..\/..\/images\/msr145\/Mini-Datalogger-MSR145_155.jpg\" alt=\"This thumb-sized Swiss Quality MSR145 data logger records over 2\u2009000\u2009000 measured values - with an optional microSD card, even over a billion measured values - and is ideal for long-term measurements. It is capable of simultaneously measuring and recording a variety of measures such as temperature, humidity, pressure, 3-axis acceleration and light. All measured values can be rapidly transferred to a PC or laptop via the USB interface or microSD card for data analysis purposes.\" width=\"155\" height=\"103\" border=\"0\"><\/a><br \/>\n<br \/>\n<a href=\"..\/..\/..\/images\/msr145\/Waterproof-datalogger-MSR145.jpg\" title=\"MSR145 data loggers are available in a variety of versions. The dimensions of the smallest housing are just 18 x 14 x 62 mm with a weight of approx. 18 g.\" class=\"msr-image-popup\" ><img loading=\"lazy\" decoding=\"async\" src=\"..\/..\/..\/images\/msr145\/Waterproof-datalogger-MSR145_155.jpg\" alt=\"MSR145 data loggers are available in a variety of versions. The dimensions of the smallest housing are just 18 x 14 x 62 mm with a weight of approx. 18 g.\" width=\"155\" height=\"96\" border=\"0\"><\/a><br \/>\n<br \/>\n<a href=\"..\/..\/..\/images\/anwendungsgebiete\/Universitaetsmedizin-Greifswald\/Datenlogger-im-Labor.jpg\" title=\"With their wide range of available measurement parameters, small size and large memory capacities, the robust data loggers from MSR Electronics GmbH provide an efficient solution for a multitude of different measuring tasks in the pharmaceutical industry as well as in many other industries.\" class=\"msr-image-popup\" ><img loading=\"lazy\" decoding=\"async\" src=\"..\/..\/..\/images\/anwendungsgebiete\/Universitaetsmedizin-Greifswald\/Datenlogger-im-Labor_155.jpg\" alt=\"With their wide range of available measurement parameters, small size and large memory capacities, the robust data loggers from MSR Electronics GmbH provide an efficient solution for a multitude of different measuring tasks in the pharmaceutical industry as well as in many other industries.\" width=\"155\" height=\"103\" border=\"0\"><\/a><\/p>\n<h2>A study of transport from blood samples in pneumatic tube systems by <a href=\"http:\/\/www2.medizin.uni-greifswald.de\/index.php?id=14&amp;L=1\" title=\"University Medicine Greifswald\" target=\"_blank\">University Medicine Greifswald (D)<\/a>.<\/h2>\n<p class=\"article_source\" style=\"margin-top:20px;\">Authors: Juliane Suchsland, Anne Greiser, Thomas Streichert, Benjamin Otto, Stefan Bollmann, Matthias Nauck, Astrid Petersmann<\/p>\n<h3>Background<\/h3>\n<p>\nPneumatic tube systems (PTS) can reduce transport time of blood samples. A new Danish PTS (TEMPUS600<sup>\u00ae<\/sup>) which does not require packing and unpacking of samples, transports samples with 10 m\/s. It allows sending of samples directly into the bulk loader of a laboratory automation system. The quality of samples can be influenced during transport and may result in preanalytical errors like hemolysis and increase of analyte concentrations such as potassium. With mini data loggers, which measure temperature, humidity, pressure and acceleration, transport conditions can be described <a href=\"#1\">[1]<\/a>. We investigated influences of TEMPUS600<sup>\u00ae<\/sup> on the quality of samples.\n<\/p>\n<h3>Methods<\/h3>\n<p>\nDuplicate blood samples of 20 volunteers were drawn. One set of samples was transported by courier and the other by PTS (TEMPUS600<sup>\u00ae<\/sup>; TIMEDICO A\/S; Bording, Denmark). During transport, a <a href=\"\/en\/product\/msr145.php\" title=\"MSR145: The revolutionary mini Data Logger\">mini data logger MSR145<\/a> (Fig. 2) (CiK Solutions GmbH; Karlsruhe, Germany) continuously measured temperature and accelerations. After transport clinical chemistry, hematology and coagulation parameters were measured, compared and the corresponding g-forces were calculated.\n<\/p>\n<figure class=\"wp-caption alignleft\">\n<a href=\"..\/..\/..\/images\/anwendungsgebiete\/Universitaetsmedizin-Greifswald\/Tempus600-Versendestation.jpg\" title=\"Fig. 1a: Tempus600\u00ae station on the ward. Source: University Medicine Greifswald\" class=\"msr-image-popup\" ><img loading=\"lazy\" decoding=\"async\" src=\"..\/..\/..\/images\/anwendungsgebiete\/Universitaetsmedizin-Greifswald\/Tempus600-Versendestation_93.jpg\" width=\"93\" height=\"86\" border=\"0\" alt=\"Fig. 1a: Tempus600\u00ae station on the ward. Source: University Medicine Greifswald\"><\/a><figcaption class=\"wp-caption-text\">Fig. 1a<\/figcaption><\/figure>\n<figure class=\"wp-caption alignleft\">\n<a href=\"..\/..\/..\/images\/anwendungsgebiete\/Universitaetsmedizin-Greifswald\/Probenrack.jpg\" title=\"Fig. 1b: Rack with samples. Source: University Medicine Greifswald\" class=\"msr-image-popup\" ><img loading=\"lazy\" decoding=\"async\" src=\"..\/..\/..\/images\/anwendungsgebiete\/Universitaetsmedizin-Greifswald\/Probenrack_93.jpg\" width=\"93\" height=\"86\" border=\"0\" alt=\"Fig. 1b: Rack with samples. Source: University Medicine Greifswald\"><\/a><figcaption class=\"wp-caption-text\">Fig. 1b<\/figcaption><\/figure>\n<figure class=\"wp-caption alignleft\">\n<a href=\"..\/..\/..\/images\/anwendungsgebiete\/Universitaetsmedizin-Greifswald\/Bulkloader.jpg\" title=\"Fig. 1c: PTS ending in the bulk loader of the laboratory automation system. Source: University Medicine Greifswald\" class=\"msr-image-popup\" ><img loading=\"lazy\" decoding=\"async\" src=\"..\/..\/..\/images\/anwendungsgebiete\/Universitaetsmedizin-Greifswald\/Bulkloader_93.jpg\" width=\"93\" height=\"86\" border=\"0\" alt=\"Fig. 1c: PTS ending in the bulk loader of the laboratory automation system. Source: University Medicine Greifswald\"><\/a><figcaption class=\"wp-caption-text\">Fig. 1c<\/figcaption><\/figure>\n<h3>Results and Discussion<\/h3>\n<p>\nThough samples in PTS were subject to maximum accelerations of ~18 g compared to ~6 g of courier transport (Fig. 3), the cumulated forces (vector sum; <a href=\"#1\">[1]<\/a>) did not reveal relevant differences between the conventional and single sample PTS. Medians of results differed less than 10% for all investigated analytes (Tab. 1). Mean relative differences of medians for LDH (lactate dehydrogenase) and free Hb (hemoglobin) were 8.1% and 6.3% respectively, both showing lower values in PTS samples. There was no difference between mean relative differences for potassium.\n<\/p>\n<figure class=\"wp-caption alignleft\">\n<a href=\"..\/..\/..\/images\/anwendungsgebiete\/Universitaetsmedizin-Greifswald\/Datenlogger-MSR145-im-Silikonschlauch.jpg\" title=\"Fig. 2: Data logger MSR145, waterproof silicon tube with 260 mAh battery.\" class=\"msr-image-popup\" ><img loading=\"lazy\" decoding=\"async\" src=\"..\/..\/..\/images\/anwendungsgebiete\/Universitaetsmedizin-Greifswald\/Datenlogger-MSR145-im-Silikonschlauch_96.jpg\" width=\"96\" height=\"86\" border=\"0\" alt=\"Fig. 2: Data logger MSR145, waterproof silicon tube with 260 mAh battery.\"><\/a><figcaption class=\"wp-caption-text\">Fig. 2<\/figcaption><\/figure>\n<figure class=\"wp-caption alignleft\">\n<a href=\"..\/..\/..\/images\/anwendungsgebiete\/Universitaetsmedizin-Greifswald\/Grafiken.jpg\" title=\"Fig. 3: G\u2013forces acting on samples during transport by courier (left) and by PTS (right); black, green and purple lines represent g-forces in x-, y\u2013 and z\u2013direction, respectively; red line represents temperature in \u00b0C. Source: University Medicine Greifswald\" class=\"msr-image-popup\" ><img loading=\"lazy\" decoding=\"async\" src=\"..\/..\/..\/images\/anwendungsgebiete\/Universitaetsmedizin-Greifswald\/Grafiken_96.jpg\" width=\"96\" height=\"86\" border=\"0\" alt=\"Fig. 3: G\u2013forces acting on samples during transport by courier (left) and by PTS (right); black, green and purple lines represent g-forces in x-, y\u2013 and z\u2013direction, respectively; red line represents temperature in \u00b0C. Source: University Medicine Greifswald\"><\/a><figcaption class=\"wp-caption-text\">Fig. 3<\/figcaption><\/figure>\n<p>\nTab. 1 &#8211; Comparison of medians and mean relative difference depending on transport type\n<\/p>\n<table class=\"result_table\">\n<thead>\n<tr>\n<th style=\"width: 25%;\">&nbsp;<\/th>\n<th style=\"width: 25%; text-align: center;\">median<br \/>courier<\/th>\n<th style=\"width: 25%; text-align: center;\">median<br \/>PTS<\/th>\n<th style=\"width: 25%; text-align: center;\">mean relative<br \/>difference [%]<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>LDH [\u03bckatal\/l]<\/td>\n<td class=\"\" style=\"text-align: center;\">3.04<\/td>\n<td class=\"\" style=\"text-align: center;\">2.79<\/td>\n<td class=\"\" style=\"text-align: center;\">8.1<\/td>\n<\/tr>\n<tr>\n<td>free hemoglobin [\u03bcmol\/l]<\/td>\n<td class=\"\" style=\"text-align: center;\">16<\/td>\n<td class=\"\" style=\"text-align: center;\">15<\/td>\n<td class=\"\" style=\"text-align: center;\">6.3<\/td>\n<\/tr>\n<tr>\n<td>potassium [mmol\/l]<\/td>\n<td class=\"\" style=\"text-align: center;\">3.9<\/td>\n<td class=\"\" style=\"text-align: center;\">3.9<\/td>\n<td class=\"\" style=\"text-align: center;\">0.0<\/td>\n<\/tr>\n<tr>\n<td>sodium [mmol\/l]<\/td>\n<td class=\"\" style=\"text-align: center;\">138.0<\/td>\n<td class=\"\" style=\"text-align: center;\">138.0<\/td>\n<td class=\"\" style=\"text-align: center;\">0.0<\/td>\n<\/tr>\n<tr>\n<td>creatinine [\u03bcmol\/l]<\/td>\n<td class=\"\" style=\"text-align: center;\">71.0<\/td>\n<td class=\"\" style=\"text-align: center;\">69.0<\/td>\n<td class=\"\" style=\"text-align: center;\">2.8<\/td>\n<\/tr>\n<tr>\n<td>glucose [mmol\/l]<\/td>\n<td class=\"\" style=\"text-align: center;\">5.4<\/td>\n<td class=\"\" style=\"text-align: center;\">5.1<\/td>\n<td class=\"\" style=\"text-align: center;\">5.6<\/td>\n<\/tr>\n<tr>\n<td>hemoglobin [mmol\/l]<\/td>\n<td class=\"\" style=\"text-align: center;\">7.9<\/td>\n<td class=\"\" style=\"text-align: center;\">7.8<\/td>\n<td class=\"\" style=\"text-align: center;\">1.3<\/td>\n<\/tr>\n<tr>\n<td>hematocrit<\/td>\n<td class=\"\" style=\"text-align: center;\">0.39<\/td>\n<td class=\"\" style=\"text-align: center;\">0.39<\/td>\n<td class=\"\" style=\"text-align: center;\">0.0<\/td>\n<\/tr>\n<tr>\n<td>platelets [Gpt\/l]<\/td>\n<td class=\"\" style=\"text-align: center;\">244.5<\/td>\n<td class=\"\" style=\"text-align: center;\">244.0<\/td>\n<td class=\"\" style=\"text-align: center;\">0.2<\/td>\n<\/tr>\n<tr>\n<td>erythrocytes [Tpt\/l]<\/td>\n<td class=\"\" style=\"text-align: center;\">4.20<\/td>\n<td class=\"\" style=\"text-align: center;\">4.25<\/td>\n<td class=\"\" style=\"text-align: center;\">&#8211; 1.2<\/td>\n<\/tr>\n<tr>\n<td>leukocytes [Gpt\/l]<\/td>\n<td class=\"\" style=\"text-align: center;\">5.87<\/td>\n<td class=\"\" style=\"text-align: center;\">5.75<\/td>\n<td class=\"\" style=\"text-align: center;\">2.0<\/td>\n<\/tr>\n<tr>\n<td>thromboplastin time [%]<\/td>\n<td class=\"\" style=\"text-align: center;\">108.0<\/td>\n<td class=\"\" style=\"text-align: center;\">109.5<\/td>\n<td class=\"\" style=\"text-align: center;\">&#8211; 1.4<\/td>\n<\/tr>\n<tr>\n<td>aPTT [s]<\/td>\n<td class=\"\" style=\"text-align: center;\">27.0<\/td>\n<td class=\"\" style=\"text-align: center;\">27.0<\/td>\n<td class=\"\" style=\"text-align: center;\">0.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Conclusion<\/h3>\n<p>\nUsing a single sample PTS noticeably decreases transport time of samples. Acceleration forces acting on samples during transport do not impact the analytical results in a clinical relevant way. Relative differences between results are within the magnitude of the imprecision of the utilized assays. The overall workflow is improved considerably by decreasing hands on time on the ward and in the laboratory without impacting sample quality.\n<\/p>\n<h3>Literature<\/h3>\n<p>\n<a name=\"1\">[1]<\/a> Streichert T, Otto B, Schnabel C, Nordholt G, Haddad M, Maric M et al. Determination of Hemolysis Thresholds by the Use of Data Loggers in Pneumatic Tube Systems. Clinical Chemistry 2011; 57(10):1390\u20137\n<\/p>\n<p style=\"margin-top:25px;\">\n<a href=\"\/en\/contact\/\" title=\"Contact MSR Electronics GmbH\">Can we also help you with your measuring tasks? We would be pleased to advise you!<\/a>\n<\/p>\n<h3>You may also be interested in these articles:<\/h3>\n<ul>\n<li><a href=\"\/en\/product\/msr145.php\" title=\"MSR145: The revolutionary mini Data Logger\">MSR145: The revolutionary mini Data Logger<\/a><\/li>\n<li><a href=\"\/en\/fields-application\/data-loggers-monitoring-shock-vibration-transport-medical-devices.html\" title=\"Quality monitoring of shocks and vibration immissions during road transport of highly sensitive medical devices\">Quality monitoring of shocks and vibration immissions during road transport of highly sensitive medical devices<\/a><\/li>\n<li><a href=\"\/en\/fields-application\/fall_detection_by_smart_phone_in_older_adults_MSR145_data_logger.html\" title=\"Fall detection by smart phone in older adults\">Fall detection by smart phone in older adults<\/a><\/li>\n<li><a href=\"\/en\/fields-application\/data_loggers_industrial_and_process_management_and_monitoring.html\" title=\"Miniaturised data loggers assist with machine, workpiece and production optimisation\">Miniaturised data loggers assist with machine, workpiece and production optimisation<\/a><\/li>\n<li><a href=\"\/en\/product\/datalogger.php\" title=\"The fast way to the right datalogger\">The fast way to the right Data Logger<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp; A study of transport from blood samples in pneumatic tube systems by University Medicine Greifswald (D). Authors: Juliane Suchsland, Anne Greiser, Thomas Streichert, Benjamin Otto, Stefan Bollmann, Matthias Nauck, Astrid Petersmann Background Pneumatic tube systems (PTS) can reduce transport &hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v22.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Data Loggers in use at Pneumatic Tube Systems<\/title>\n<meta name=\"description\" content=\"MSR Data loggers in use in a study of transport from blood samples in pneumatic tube systems\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.msr.ch\/en\/data-logger-measure-acceleration-in-pneumatic-tube-transport\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Data Loggers in use at Pneumatic Tube Systems\" \/>\n<meta property=\"og:description\" content=\"MSR Data loggers in use in a study of transport from blood samples in pneumatic tube systems\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.msr.ch\/en\/data-logger-measure-acceleration-in-pneumatic-tube-transport\/\" \/>\n<meta property=\"og:site_name\" content=\"EN MSR Data loggers\" \/>\n<meta property=\"article:published_time\" content=\"2017-06-25T15:30:16+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2017-06-25T15:56:12+00:00\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.msr.ch\/en\/data-logger-measure-acceleration-in-pneumatic-tube-transport\/\",\"url\":\"https:\/\/www.msr.ch\/en\/data-logger-measure-acceleration-in-pneumatic-tube-transport\/\",\"name\":\"Data Loggers in use at Pneumatic Tube Systems\",\"isPartOf\":{\"@id\":\"https:\/\/www.msr.ch\/en\/#website\"},\"datePublished\":\"2017-06-25T15:30:16+00:00\",\"dateModified\":\"2017-06-25T15:56:12+00:00\",\"author\":{\"@id\":\"https:\/\/www.msr.ch\/en\/#\/schema\/person\/9f5e8ed5c17dd1588344ef6ea5492ed7\"},\"description\":\"MSR Data loggers in use in a study of transport from blood samples in pneumatic tube systems\",\"breadcrumb\":{\"@id\":\"https:\/\/www.msr.ch\/en\/data-logger-measure-acceleration-in-pneumatic-tube-transport\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.msr.ch\/en\/data-logger-measure-acceleration-in-pneumatic-tube-transport\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.msr.ch\/en\/data-logger-measure-acceleration-in-pneumatic-tube-transport\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.msr.ch\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Evaluation of a fast single sample pneumatic tube system\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.msr.ch\/en\/#website\",\"url\":\"https:\/\/www.msr.ch\/en\/\",\"name\":\"EN MSR Data loggers\",\"description\":\"MSR Electronics GmbH\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.msr.ch\/en\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.msr.ch\/en\/#\/schema\/person\/9f5e8ed5c17dd1588344ef6ea5492ed7\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/www.msr.ch\/en\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/2d44aa9cd968ccac7142267b4b988313?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/2d44aa9cd968ccac7142267b4b988313?s=96&d=mm&r=g\",\"caption\":\"admin\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Data Loggers in use at Pneumatic Tube Systems","description":"MSR Data loggers in use in a study of transport from blood samples in pneumatic tube systems","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.msr.ch\/en\/data-logger-measure-acceleration-in-pneumatic-tube-transport\/","og_locale":"en_GB","og_type":"article","og_title":"Data Loggers in use at Pneumatic Tube Systems","og_description":"MSR Data loggers in use in a study of transport from blood samples in pneumatic tube systems","og_url":"https:\/\/www.msr.ch\/en\/data-logger-measure-acceleration-in-pneumatic-tube-transport\/","og_site_name":"EN MSR Data loggers","article_published_time":"2017-06-25T15:30:16+00:00","article_modified_time":"2017-06-25T15:56:12+00:00","author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"admin","Estimated reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.msr.ch\/en\/data-logger-measure-acceleration-in-pneumatic-tube-transport\/","url":"https:\/\/www.msr.ch\/en\/data-logger-measure-acceleration-in-pneumatic-tube-transport\/","name":"Data Loggers in use at Pneumatic Tube Systems","isPartOf":{"@id":"https:\/\/www.msr.ch\/en\/#website"},"datePublished":"2017-06-25T15:30:16+00:00","dateModified":"2017-06-25T15:56:12+00:00","author":{"@id":"https:\/\/www.msr.ch\/en\/#\/schema\/person\/9f5e8ed5c17dd1588344ef6ea5492ed7"},"description":"MSR Data loggers in use in a study of transport from blood samples in pneumatic tube systems","breadcrumb":{"@id":"https:\/\/www.msr.ch\/en\/data-logger-measure-acceleration-in-pneumatic-tube-transport\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.msr.ch\/en\/data-logger-measure-acceleration-in-pneumatic-tube-transport\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.msr.ch\/en\/data-logger-measure-acceleration-in-pneumatic-tube-transport\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.msr.ch\/en\/"},{"@type":"ListItem","position":2,"name":"Evaluation of a fast single sample pneumatic tube system"}]},{"@type":"WebSite","@id":"https:\/\/www.msr.ch\/en\/#website","url":"https:\/\/www.msr.ch\/en\/","name":"EN MSR Data loggers","description":"MSR Electronics GmbH","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.msr.ch\/en\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/www.msr.ch\/en\/#\/schema\/person\/9f5e8ed5c17dd1588344ef6ea5492ed7","name":"admin","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.msr.ch\/en\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/2d44aa9cd968ccac7142267b4b988313?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2d44aa9cd968ccac7142267b4b988313?s=96&d=mm&r=g","caption":"admin"}}]}},"_links":{"self":[{"href":"https:\/\/www.msr.ch\/en\/wp-json\/wp\/v2\/posts\/1524"}],"collection":[{"href":"https:\/\/www.msr.ch\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.msr.ch\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.msr.ch\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.msr.ch\/en\/wp-json\/wp\/v2\/comments?post=1524"}],"version-history":[{"count":7,"href":"https:\/\/www.msr.ch\/en\/wp-json\/wp\/v2\/posts\/1524\/revisions"}],"predecessor-version":[{"id":1531,"href":"https:\/\/www.msr.ch\/en\/wp-json\/wp\/v2\/posts\/1524\/revisions\/1531"}],"wp:attachment":[{"href":"https:\/\/www.msr.ch\/en\/wp-json\/wp\/v2\/media?parent=1524"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.msr.ch\/en\/wp-json\/wp\/v2\/categories?post=1524"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.msr.ch\/en\/wp-json\/wp\/v2\/tags?post=1524"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}