MSR Modular Signal Recorder
   
 
 
MSR145 Datasheet PDF

MSR145 Analogue
with 2 inputs
 PDF

MSR145 Analogue
with 4 inputs
 PDF

MSR145 Analogue
voltage divider
 PDF

Strap and Screw fastening for MSR145 PDF

MSR145 Pricelist

MSR PC software

MSR Firmware update
 
 
Recommend MSR145!
 
 
Bild MSR145
 
MSR145 datalogger wins 'Elektronik product of the year'
 

The solution for efficient measurement data logging.

 
 

MSR145: The revolutionary mini Data Logger

This thumb-sized Swiss Quality MSR145 data logger records over 2 000 000 measured values - with an optional microSD card, even over a billion measured values - and is ideal for long-term measurements. It is capable of simultaneously measuring and recording a variety of measures such as temperature, humidity, pressure, 3-axis acceleration and light. All measured values can be rapidly transferred to a PC or laptop via the USB interface or microSD card for data analysis purposes.

Versatile universal data logger

You have the choice between different casings, battery capacities and sensors. Additionally, you can equip your MSR logger with analogue inputs (selectable input configuration). The analogue inputs allow you to connect individual, external sensors for different measuring tasks (e.g., CO2, conductivity, pH, etc.). In addition to your MSR145 data logger you will also receive the user-friendly software for data acquisition and analysis free of charge.

With a few clicks you are able to select and request a no-obligation quotation of your desired MSR145.

  1. Select the housing and the corresponding battery.
  2. Select the sensors.
  3. Do you require 2 or 4 analogue inputs?
  4. Would you like to expand the memory capacity of your MSR145 to over 1 billion measured values?
  5. Contact us for prices and delivery terms!
  6. General technical data on the MSR145.

1. Select the housing and the corresponding battery.

Housing Type and battery Picture Size & weight Medium Sheat material Item‑no.
Standard
IP 60
Design housing
with 260 mAh battery
Data logger MSR145, design housing with 260 mAh battery 27 x 16 x 53 mm
(W x H x L)
approx. 20 g
Air PC, not
encapsulated
145B15
Design housing
with 900 mAh battery
Data logger MSR145, design housing with 900 mAh battery 39 x 23 x 72 mm
(W x H x L)
approx. 56 g
Air PC, not
encapsulated
145B7
Waterproof
IP 67
Silicon tube
with 260 mAh battery
Data logger MSR145, waterproof silicon tube with 260 mAh battery 18 x 14 x 62 mm
(W x H x L)
approx. 18 g
Air,
various liquids
Silicon,
encapsulated
145B4
Design housing
with 260 mAh battery
Data logger MSR145, waterproof design housing with 260 mAh battery 27 x 16 x 53 mm
(W x H x L)
approx. 27 g
Air,
various liquids
PC,
encapsulated
145B16
Design housing
with 900 mAh battery
Data logger MSR145, waterproof design housing with 900 mAh battery 39 x 23 x 72 mm
(W x H x L)
approx. 64 g
Air,
various liquids
PC,
encapsulated
145B8

2. Select the sensors.

Please select the sensors for your data logger here. For the measured parameters temperature, humidity and fluid pressure you can now choose whether you wish to provide your MSR145 data logger with more than one sensor of the same measured parameter. Please note the following restrictions for this option:

  • Only one measured parameter can be equipped with multiple sensors.
  • The slot for a microSD card cannot be combined with this option.
  • The light sensor (L), the temperature sensor (FT) and the port for a thermal element of Type K (T3, T4) cannot be selected.

Can your desired sensor combination not be selected? Contact us for a customized fit.

Measured parameter /
Measuring/storage rate
Working range /
Accuracy
Internal
sensor
External sensor (according to cable length)
0.20 m 1.00 m 1.60 m
Temperature

1/s up to
one sample every 12 h
-10...+58 °C
±0.1 °C (+5...+45 °C)
±0.2 °C (-10...+58 °C)
only available
externally
Item no. FT/020
Item no. FT/100
Item no. FT/160
external: -55...+125 °C
internal: -20...+65 °C

±0.5 °C (-10...+65 °C)
±2 °C (-55...+125 °C)
Item no. T2
Item no. FT2/020

Item no. FT2/100

Item no. FT2/160

Connector for thermal
element of Type K

(without sensor)
Cannot be selected
at the same time as the
temperature sensor.

1/s up to
one sample every 12 h
1 x
-200...+1350 °C
only available
externally
Item no. FT3/020
Item no. FT3/100
Item no. FT3/160
4 x
-200...+1350 °C
only available
externally
Item no. FT4/020
Item no. FT4/100
Item no. FT4/160
Humidity
with integrated temperature

1/s up to
one sample every 12 h
0...100 % rel. humidity
external: -20...+85 °C
internal: -20...+65 °C

±2 % rel. humidity
(10...85 %, 0...+40 °C)
±4 % rel. humidity
(85...95 %, 0...+40 °C)
Item no. H
Item no. FH/020

Item no. FH/100

Item no. FH/160

Air pressure absolute,
with integrated temperature

10/s up to
one sample every 12 h
0...2000 mbar abs.
external: -20...+85 °C
internal: -20...+65 °C

±2.5 mbar
(750...1100 mbar abs.,
+25 °C)
Item no. P
Item no. FP/020
Item no. FP/100
Item no. FP/160
0...14 bar absolute
-20...+65 °C

±50 mbar
(1...10 bar abs., +25 °C)
Item no. P2
only available
internally
only available
internally
only available
internally
Fluid pressure
with integrated temperature

20/s up to
one sample every 12 h

Material in contact with media:
  • Stainless Steel AISI 316L
    (DIN 1.4404 / 1.4435)
  • O-rings: Viton® 70° Shore
0...3000 mbar abs.
-20...+85 °C

±30 mbar
only available
externally
Item no. FP3/020

Item no. FP3/100

Item no. FP3/160

0...30 bar absolute
-20...+85 °C

±300 mbar
only available
externally
Item no. FP4/020

Item no. FP4/100

Item no. FP4/160

3-axis-acceleration

50/s up to
one sample every 12 h
±15 g
-20...+65 °C

±0.15 g (0...5 g, +25 °C)
±0.25 g (5...10 g, +25 °C)
±0.45 g (10...15 g, +25 °C)
Item no. A
Item no. FA/020
Item no. FA/100
Item no. FA/160
3-axis-acceleration
with fast peak (1 kHz)


50/s up to
one sample every 12 h
Item no. A4
Item no. FA4/020
Item no. FA4/100
Item no. FA4/160
Light

1/s up to
one sample every 12 h
0...65 000 lx
max. sensitivity
at 500 nm
Item no. L2
Item no. FL2/020
Item no. FL2/100
Item no. FL2/160

3. Do you require 2 or 4 analogue inputs?

Should you wish to connect additional third-party external sensors to your MSR145 datalogger then please indicate here whether you require two or four analogue inputs.

Analogue inputs Inputs Input configuration Item no.
Screw terminal for 4 analogue inputs.

Including alarm output and input for starting
and stopping data recording.

Measurement/storage rate:
50/s up to one sample every 12 h

Not available combinations:
  • Analogue inputs with thermal element
  • Analogue inputs with light and temperature
2 analogue inputs
(resolution: 12 Bit)
0...3.0 V - standard E33
4 analogue inputs
(resolution: 12 Bit)
0...3.0 V - standard E3333
2 analogue inputs
(resolution: 12 Bit)
Select the number of inputs for the
respective input configuration:

(1)   0...20 mA
(2)   4...20 mA
(3)   0...3.0 V
(4)   0.5...4.5 V / 0...5.0 V
(5)   0...10.0 V / 1.0...6.0 V
(6)   0...12.0 V
(7)   0...24.0 V
Exx
4 analogue inputs
(resolution: 12 Bit)
Exxxx

4. Would you like to expand the memory capacity of your MSR145 to over 1 billion measured values?

Please order the expansion slot for plugging-in a standard microSD card here. Item no.
Expansion slot for microSD card (available only for design housing B7 and B8)

Please note that:
  • this expansion slot with plugged-in microSD card only meets the protection category IP60,
    even with the design housing B8,
  • the expansion slot is not available in combination with light or thermal element,
  • the expansion slot is not available in combination with a multiple selection of sensors of the same measurand,
  • one formatted and ready for use microSD card (≥4GB) is included.
N10006

5. Contact us for prices and delivery terms!

Make a price enquiry by telephone, fax or e-mail

The following codes denote the type of datalogger and sensors you have selected. When making price enquiries by telephone, fax or e-mail, please contact the dealership in your country and have the codes ready.

List of the international dealerships

Code for the datalogger and the sensors:

            

Making price enquiries using the contact form

Please provide us with your contact details on the following online form and send your enquiry with a click of your mouse – we will be pleased to send you a no-obligation quotation!

Item no.    
Title*  
First name    
Surname*    
Company    
Industry  
Number, street    
Zip code/postcode    
City    
Country*    
Phone    
Fax    
E-mail*    
 
Notes (please enter the number of units you require here):
 

*Mandatory fields

6. General technical data on the MSR145.

Memory capacity: Over 2 000 000 measured values – expandable to over 1bn.
Key: Set bookmark or start and stop recording.
LED:  
blue:
red:
yellow:
Record indicator
Alarm indicator
Battery charge indicator
Power supply:
  • Lithium-polymer battery, 260 mAh or 900 mAh.
  • The battery is charged via the USB connection.
  • One battery charge is sufficient for operation of the unit for up to two years, depending on the battery and the measurement rate.
Options: Charging station (USB hub) for 7 MSR145 (item number B47002)
Interface: USB
PC software: Free Setup, Reader, Viewer and Online software (Windows XP/Vista/7/8/10) to record and evaluate data. All measurement parameters can be rapidly transferred to a PC via USB connection both during the measurement operation and once the measurement task has been completed. Thanks to the integrated clock (RTC), data from as many MSR145 units as required can be synchronised and merged into a single data record.
Operating conditions:
Temperature: -20...+65 °C
Optimum storage conditions:
Temperature:
Humidity:
+5...+45 °C (ideal storage conditions for the battery)
10...95 % relative humidity, non-condensing
Standards: The MSR145 complies with EU-Directives RoHS / WEEE.

 

More questions? Then contact us!