MSR Modular Signal Recorder
   
 
 
MSR145 Datasheet   PDF

MSR145 Analogue
with 2 inputs
  PDF

MSR145 Analogue
with 4 inputs
  PDF

MSR145 Analogue
voltage divider
  PDF

Strap and Screw fastening for MSR145   PDF

MSR145 Pricelist

MSR PC software

MSR Firmware update
 
 
Recommend MSR145!
 
 
Bild MSR145
 
MSR145 datalogger wins 'Elektronik product of the year'
The solution for efficient measurement data logging.  
 

MSR145: The revolutionary mini datalogger

This thumbsized quality datalogger records over 2 000 000 measurement parameters and is capable of simultaneously measuring and recording the five primary physical variables temperature, humidity, pressure, 3-axis acceleration and light. With the optional microSD card you can expand the memory capacity of your MSR145 to over one billion measurement parameters. If you wish to connect between two and four additional external third-party sensors to your datalogger then simply select the corresponding expansion unit.

You pay only for what you really need!


Configure your own custom MSR145 variant here and request a no-obligation quotation with just a few clicks:

  1. Select the housing and the corresponding battery.
  2. Select the type of sensors (internal and external).
  3. Do you require external sensors instead of internal ones?
  4. Do you require an additional 2 or 4 analogue inputs for connecting third-party sensors?
  5. Would you like to expand the memory capacity of your MSR145 to over 1 billion measurement parameters?
  6. Contact us for prices and terms of delivery!
  7. General technical data on the MSR145


1. Select the housing and the corresponding battery.


Housing Type and battery Picture Size & weight Medium Sheat material Item‑no.
Standard
IP 60
Design housing
with 260 mAh battery
MSR145S 20 x 15 x 52 mm
approx. 16 g
Air PC, not
encapsulated
145B5
Design housing
with 900 mAh battery
MSR145 900 mAh 39 x 23 x 72 mm
approx. 56 g
Air PC, not
encapsulated
145B7
Waterproof
IP 67
Silicon tube
with 260 mAh battery
MSR145W 18 x 14 x 62 mm
approx. 18 g
Air,
various liquids
Silicon,
encapsulated
145B4
Design housing
with 260 mAh battery
MSR145WS 20 x 15 x 61 mm
approx. 23 g
Air,
various liquids
PC,
encapsulated
145B6
Design housing
with 900 mAh battery
MSR145 900 mAh 39 x 23 x 72 mm
approx. 64 g
Air,
various liquids
PC,
encapsulated
145B8


2. Select the type of sensors (internal and external).


Please select which sensors should be fitted to your datalogger:

Measured parameters Working range Accuracy Measurement/
storage rate
Item no.
Temperature internal: -20...+65 °C ±0.5 °C (-10...+65 °C) 1/s up to one sample
every 12 h
T

external: -10...+58 °C ±0.1 °C (+5...+45 °C)
±0.2 °C (-10...+58 °C)
external: -55...+125 °C ±0.5 °C (-10...+65 °C)
±2 °C (-55...+125 °C)
external: 1 or 4 connectors for K-type thermocouples
(excluding sensor) 0...+1024 °C
Relative humidity
with integrated temperature
0...100 % rel. humidity
-20...+65 °C
±2 % rel. humidity (10...85 %, 0...+40 °C)
±4 % rel. humidity (85...95 %, 0...+40 °C)
1/s up to one sample
every 12 h
H

Pressure absolute,
with integrated temperature
0...2000 mbar absolute
-20...+65 °C
±2.5 mbar
(750...1100 mbar absolute, +25 °C)
10/s up to one sample
every 12 h
P
optional:
0...14 bar absolute
-20...+65 °C
±50 mbar (1...10 bar absolute, +25 °C) P2
3-axis-acceleration
(attitude)
±15 g
-20...+65 °C
±0.15 g (+25 °C) 50/s up to one sample
every 12 h
A
Light 0...65 000 lx max. sensitivity at 500 nm 1/s up to one sample
every 12 h
L


3. Do you require external sensors instead of internal ones?


Instead of the internal temperature, humidity, pressure, 3-axis-acceleration and light sensors you may optionally select the corresponding external sensors for the MSR145 datalogger.

External sensor Working range Cable length
0.15 m 0.40 m 1.00 m 1.60 m
Temperature -10...+58 °C Item no. FT/015
Item no. FT/040
Item no. FT/100
Item no. FT/160
-55...+125 °C Item no. FT2/015
Item no. FT2/040
Item no. FT2/100
Item no. FT2/160
or (instead of
temperature sensor):
Connector for thermal
element of Type K

(without sensor)
1 x
0...+1024 °C
Item no. FT3/015
Item no. FT3/040
Item no. FT3/100
Item no. FT3/160
4 x
0...+1024 °C
Item no. FT4/015
Item no. FT4/040
Item no. FT4/100
Item no. FT4/160
Humidity 0...100 % rel. humidity Item no. FH/015
Item no. FH/040
Item no. FH/100
Item no. FH/160
Air pressure 2.0 bar Item no. FP/015
Item no. FP/040
Item no. FP/100
Item no. FP/160
14 bar Item no. FP2/015
Item no. FP2/040
Item no. FP2/100
Item no. FP2/160
3-axis-acceleration ±15 g Item no. FA/015
Item no. FA/040
Item no. FA/100
Item no. FA/160
Light 0...65 000 lx Item no. FL/015
Item no. FL/040
Item no. FL/100
Item no. FL/160


4. Do you require an additional 2 or 4 analogue inputs for connecting third-party sensors?


Should you wish to connect additional third-party external sensors to your MSR145 datalogger then please indicate here whether you require two or four analogue inputs.

Analogue inputs Inputs Input configuration Item no.


Including alarm output and input for starting
and stopping data recording.

Measurement/storage rate:
50/s up to one sample every 12 h

Not available combinations:
  • Analogue inputs with thermal element
  • Analogue inputs with light and temperature
2 analogue inputs
(resolution: 12 Bit)
0...3.0 V - standard E33
4 analogue inputs
(resolution: 12 Bit)
0...3.0 V - standard E3333
2 analogue inputs
(resolution: 12 Bit)
Select the number of inputs for the
respective input configuration:

(1)   0...20 mA
(2)   4...20 mA
(3)   0...3.0 V
(4)   0.5...4.5 V / 0...5.0 V
(5)   0...10.0 V / 1.0...6.0 V
(6)   0...12.0 V
(7)   0...24.0 V
Exx
4 analogue inputs
(resolution: 12 Bit)
Exxxx


5. Would you like to expand the memory capacity of your MSR145 to over 1 billion measurement parameters?


Please order the expansion slot for plugging-in a standard microSD card here. Item no.
Expansion slot for microSD card (available only for design housing B7 and B8)

Please note that:
  • this expansion slot with plugged-in microSD card only meets the protection category IP60,
    even with the design housing B8,
  • the expansion slot is not available in combination with light or thermal element,
  • one formatted and ready for use microSD card (≥4GB) is included.
N10006


6. Contact us for prices and terms of delivery!


Make a price enquiry by telephone, fax or e-mail

The following codes denote the type of datalogger and sensors you have selected. When making price enquiries by telephone, fax or e-mail, please contact the dealership in your country and have the codes ready.

List of the international dealerships

Code for the datalogger and the sensors:

            


Making price enquiries using the contact form

Please provide us with your contact details on the following online form and send your enquiry with a click of your mouse – we will be pleased to send you a no-obligation quotation!

Item no.    
Title*  
First name    
Surname*    
Company    
Number, street    
Zip code/postcode    
City    
Country*    
Phone    
Fax    
E-mail*    
 
Notes (please enter the number of units you require here):
 

*Mandatory fields



7. General technical data on the MSR145


Memory capacity: Over 2 000 000 measurement parameters.
Key: Set bookmark or start and stop recording.
LED:  
blue:
red:
yellow:
Record indicator
Alarm indicator
Battery charge indicator
Power supply:
  • Lithium-polymer battery, 260 mAh or 900 mAh.
  • The battery is charged via the USB connection.
  • One battery charge is sufficient for operation of the unit for up to two years, depending on the battery and the measurement rate.
Options: Charging station (USB hub) for 7 MSR145 (item number B47002)
Interface: USB
PC software: Free Setup, Reader, Viewer and Online software (Windows 2000/XP/Vista/7) to record and evaluate data. All measurement parameters can be rapidly transferred to a PC via USB connection both during the measurement operation and once the measurement task has been completed. Thanks to the integrated clock (RTC), data from as many MSR145 units as required can be synchronised and merged into a single data record.
Operating conditions:
Temperature: -20...+65 °C
Optimum storage conditions:
Temperature:
Humidity:
+5...+45 °C (ideal storage conditions for the battery)
10...95 % relative humidity, non-condensing
Standards: The MSR145 complies with EU-Directives RoHS / WEEE.

 

More questions? Then contact us!