MSR Modular Signal Recorder
   
 
 
MSR255 Datasheet PDF
 
 
Recommend MSR255!
 
 
MSR255 datalogger: Robust all-rounder with LCD screen
 
MSR255 datalogger: Robust all-rounder with LCD screen
 
Datalogger MSR255 with three external sensors (temperature, humidity, pressure)
The solution for efficient measurement data logging.  
 

MSR255 Data Logger: Robust multi-talent with LCD screen

With up to five different sensors, four additional analogue inputs and an easy to read LCD screen the compact MSR255 offers maximum possible flexibility and user-friendliness.


5 sensors, 4 analogue inputs


The measuring tasks undertaken by the user define the way in which the MSR255 is configured: There is a choice of temperature, humidity, air pressure and light sensors (fitted internally within the case or externally on a cable) together with a sensor for measuring acceleration in all three co-ordinate axes. Acceleration values can be measured at 3200 Hz and saved at a frequency of approx. 50 Hz following digital filtration. In addition, the voltage of four further external analogue channels or sensors can also be recorded. The analogue inputs feature an alarm output, multiple output switching power supply and an input for starting and stopping data recording.

The memory capacity of the MSR255 is over 2 million measurement parameters. Thanks to its high-capacity lithium polymer battery the data logger is ideal for long-term data acquisition applications. The 4-row backlit LCD display has four individually configurable views. All acquired data can be quickly transferred to a PC or laptop via the USB interface.


Configure your own custom MSR255 variant here and request a no-obligation quotation with just a few clicks:

  1. Basic specification and technical data for the MSR255
  2. Select the measurement parameters for the sensors (internal and external).
  3. Do you require external sensors instead of internal ones?
  4. Do you require an additional 4 analogue inputs for connecting third-party sensors?
  5. Contact us for prices and terms of delivery!


1. Basic specification and technical data for the MSR255


Housing
Technical data Item no.
Datenlogger MSR255: Robustes Multitalent mit LC-Anzeige

Standard IP 60
PC, not encapsulated
Housing: Anodised aluminium industrial case with top-hat rail snapper (TS35)
Size & weight: 78 x 62 x 38 mm, approx. 222 g
 
Memory capacity: Over 2 000 000 measurement parameters
 
Operation: Two keys for selecting functions and controlling data recording
Display: Four row LCD matrix display
LED: 3 colour LED to indicate data recording, alarm and charge condition
 
Integrated sensors: Selection of different sensors for temperature, relative humidity,
pressure, light and 3-axis acceleration/position
Measurement rate (MR): 1 /s to every 12 h (acceleration up to 3200 /s)
Storage rate (SR): 1 /s to every 12 h (acceleration up to 50 /s)
 
Power supply: Rechargeable lithium polymer battery 2300 mAh, external power supply unit
Interface: USB (Mini-B)
PC software: Free Setup, Reader, Viewer- & Online software
(Windows 2000/XP/Vista/7)
 
Operating conditions:   Temperature -20...+65 °C
Storage conditions:
  • Temperature +5...+45 °C (ideal storage condition for the battery)
  • 10...95 % relative humidity, non-condensing
 
Standards: The MSR255 complies with EU-Directives RoHS / WEEE.

255B10

Datenlogger MSR255: Robustes Multitalent mit LC-Anzeige

Waterproof IP 67
PC, encapsulated
(from October 2011)

255B11



2. Select the measurement parameters for the sensors (internal and external).


You can specify your MSR255 with up to five different sensors. Please select your desired measurement parameters here.

Measured
parameters
Working range Accuracy Measurement/
storage rate
Item no.
Temperature internal: -20...+65 °C
external: -55...+125 °C
±0.5 °C (-10...+65 °C)
±2 °C (-55...+125 °C)
1/s up to one sample
every 12 h
T
Relative humidity
with integrated
temperature
0...100 % rel. humidity
-20...+65 °C
±2 % rel. humidity
(10...85 % rel. humidity, 0...+40 °C)
±4 % rel. humidity
(85...95 % rel. humidity, 0...+40 °C)
1/s up to one sample
every 12 h
H
Pressure absolute,
with integrated
temperature
0...2000 mbar absolute
-20...+65 °C
±2.5 mbar
(750...1100 mbar absolute, +25 °C)
1/s up to one sample
every 12 h
P
optional:
0...14 bar absolute
-20...+65 °C
±50 mbar
(1...10 bar absolute, +25 °C)
P2
3-axis-acceleration ±15 g ±0.15 g (+25 °C) Acceleration: 50/s (3200/s)
Attitude:
1 /s up to every 12 h
A
Light 0...65 000 lx max. sensitivity at 500 nm 1/s up to one sample
every 12 h
L


3. Do you require external sensors instead of internal ones?


Instead of the internal temperature, humidity, air pressure, 3-axis-acceleration and light sensors you may optionally select the corresponding external sensors (not pluggable) for the MSR255 datalogger.

External sensor Working range Cable length
0.15 m 0.40 m 1.00 m 1.60 m
Temperature -55...+125 °C Item no. FT2/015
Item no. FT2/040
Item no. FT2/100
Item no. FT2/160
Humidity 0...100 % rel. humidity Item no. FH/015
Item no. FH/040
Item no. FH/100
Item no. FH/160
Air pressure 2.0 bar Item no. FP/015
Item no. FP/040
Item no. FP/100
Item no. FP/160
14 bar Item no. FP2/015
Item no. FP2/040
Item no. FP2/100
Item no. FP2/160
3-axis-acceleration ±15 g Item no. FA/015
Item no. FA/040
Item no. FA/100
Item no. FA/160
Light 0...65 000 lx Item no. FL/015
Item no. FL/040
Item no. FL/100
Item no. FL/160


4. Do you require an additional 4 analogue inputs for connecting third-party sensors?


It is possible to expand the range of possible applications for which your MSR255 can be used by specifying four analogue inputs. These additional inputs allow external sensors for a wide range of measuring tasks to be connected. If required, these third-party sensors can be powered by the logger's internal battery. The power can be automatically turned on before measurements take place with a pre-settable lead time. This allows any necessary warm-up periods for the sensors to be taken into consideration.

Analogue inputs Inputs Input configuration Item no.
Including an alarm output, multiple output
switching power supply and an input for
starting and stopping data recording.

Measurement/storage rate:
1/s to every 12 h
4 analogue inputs
(resolution: 12 Bit)
0...3.0 V - standard E3333
4 analogue inputs
(resolution: 12 Bit)
Select the number of inputs for the
respective input configuration:

(1)   0...20 mA
(2)   4...20 mA
(3)   0...3.0 V
(4)   0.5...4.5 V / 0...5.0 V
(5)   0...10.0 V / 1.0...6.0 V
(6)   0...12.0 V
(7)   0...24.0 V
Exxxx


5. Contact us for prices and terms of delivery!


Make a price enquiry by telephone, fax or e-mail

The following codes denote the type of datalogger and sensors you have selected. When making price enquiries by telephone, fax or e-mail, please contact the dealership in your country and have the codes ready.

List of the international dealerships

Code for the datalogger MSR255 and the sensors:

            


Making price enquiries using the contact form

Please provide us with your contact details on the following online form and send your enquiry with a click of your mouse – we will be pleased to send you a no-obligation quotation!

Item no.    
Title*  
First name    
Surname*    
Company    
Number, street    
Zip code/postcode    
City    
Country*    
Phone    
Fax    
E-mail*    
 
Notes (please enter the number of units you require here):
 

*Required fiels

 